Micro- and nanomechanical resonators are emerging as promising platforms for quantum technologies, precision sensors and fundamental science experiments.

Micro- and nanomechanical resonators are emerging as promising platforms for quantum technologies, precision sensors and fundamental science experiments. To utilize these devices for force sensing or quantum optomechanics, they must be brought in close proximity with other systems for functionalization or efficient readout. Improved understanding of the loss mechanisms in nanomechanical resonators, specifically the advent of dissipation dilution, has led to the development of ultracohorent devices with mechanical quality factors exceeding one billion at room temperature, setting their force sensitivities surpassing those of the state-of-the-art atomic force microscopes. Given this new regime of sensitivity, an intriguing question is whether the proximity of other materials hinders mechanical coherence. Here we report a dissipation mechanism that occurs in ultracoherent nanomechanical oscillators caused by the presence of nearby dielectrics. By studying the parameter scaling of the effect, we show that the mechanism is more severe for low-frequency mechanical modes. This is due to dielectric loss within the materials caused by the motion of a resonator carrying static charges. These observations are consistent with the non-contact friction observed in atomic force microscopes. Our findings provide insights into limitations on the integration of ultracoherent nanomechanical resonators and highlight the adverse effects of charged defects in these systems. Micro- and nanomechanical oscillators have long been used in science and technology alike, as they can couple to a wide range of other degrees of freedom. However, their miniaturization renders them more susceptible to dissipative mechanisms. Reaching quality factors beyond 109, comparable to those in bulk systems1, was not achieved in micro- and nanomechanical resonators until recently2,3,4,5,6,7. A large family of ultrahigh-Qresonators is based on flexural modes of tensioned and high-aspect-ratio structures (that is, membranes and strings)8. In these resonators, dissipation dilution, a phenomenon first introduced in the gravitational wave detector community9, enhances the quality factor of the modes by many orders of magnitude beyond the material’s intrinsic quality factor10. String-like resonators with soft-clamped modes4,5,6,11,12are particularly promising force sensors as they exhibit both low mass (m, in the sub-nanogram range) and low damping rate (Γm< 1 mHz). The thermal-limited force sensitivity of mechanical oscillators at temperatureTis commonly defined as the single-sided spectrum of the thermal force, that is,SFth=4kBTmΓm\sqrt{{S}_{{\rm{F}}}^{\mathrm{th}}}=\sqrt{4{k}_{{\rm{B}}}Tm{\varGamma }_{m}}, wherekBis the Boltzmann constant. For these ultracoherent devices, it reaches values below1 aN/Hz1\,\mathrm{aN}/\sqrt{\mathrm{Hz}}at room temperature4, surpassing the sensitivity level of the state-of-the-art atomic force microscope (AFM) cantilevers13. Virtually all applications that require low mechanical dissipation rely on short-range interactions and require placing other objects at sub-micron distances from the nanomechanical resonator. For example, measurements of Casimir forces14, tests of gravity at short distances15and precision scanning force microscopy experiments16,17all occur at short distances. Moreover, as illustrated in Fig.1a–c, several platforms for coupling nanomechanical resonators to other degrees of freedom, such as spin qubits18,19, superconducting circuits20and optical microcavities21,22,23,24,25also rely on near-field interactions. The latter is of particular interest as the optomechanical coupling, which enables readout of the motion of the resonator with quantum-limited precision26, scales exponentially with the distance between optical and mechanical resonators. So far, the devices used in these applications16,17,18,19,21,22,23,24,25do not exhibit the force sensitivities,SFth{S}_{{\rm{F}}}^{\mathrm{th}}, as low as those of the stand-alone ultrahigh-Qdevices discussed previously, which are suspended tens of micrometres away from the closest object. This naturally raises the question whether ultracoherent mechanical devices, with force sensitivity below that of AFMs, can retain their coherence properties near other materials. a–c, Schematics of platforms for coupling nanomechanical resonators to spins in solids18(a), superconducting circuits20(b) and nanophotonics cavities23(c). In these platforms there are dielectric materials close to the resonator.d, Even in the absence of any external objects, the dielectrics on the substrate can also introduce loss.e, Dielectric loss within the substrate limiting the quality factor of ultracoherent strings as a function of the string-substrate distanced(shown inf). The colours blue, red and green correspond to (1) strained-engineered11, (2) hierarchical12and (3) polygon4designs, shown in the right hand side. These modes have effective masses of 5, 46 and 24 pg, respectively. The ribbons correspond to the estimated NCF-limited quality factor for the frequency and geometry of each design, suspended above a silicon substrate with a 4-nm native SiO2layer. The filled and empty markers correspond to the measured and simulated quality factors adapted from the references.f, Concept of dielectric-induced mechanical loss. The charged nanomechanical resonator makes an electric field, which polarizes the dielectrics nearby. This field couples the motion of the resonator to the lossy polarization of the dielectric, which results in dissipation of the mechanical energy within the dielectic. In this work, we show that nearby dielectrics do perturb nanomechanical resonators. We report on a loss mechanism occurring when ultracoherent string resonators are integrated in the near-field of a photonic crystal (PhC) cavity. We observe that the quality factor of the high-Qmodes of a binary-tree-shaped resonator12is reduced for smaller cavity-resonator separations. Moreover, for millimetre-long strings, even the presence of the substrate supporting the structures can cause additional loss in the low-frequency modes. By identifying that the added loss is inversely proportional to the mechanical mode’s frequency, we realize that it is due to an electrical interaction between the resonator and the dielectrics in its proximity (that is, the optical cavity or the substrate) mediated by static charges. This phenomenon, also known as non-contact friction (NCF), has only been observed in AFM cantilevers27,28,29,30, where a functionalized tip is brought in close distance from a sample to measure surface properties. In nanomechanical systems, outside the context of AFMs, these effects have been largely overlooked due to larger inter-body distances and the fact that most resonators are not intentionally charged. However, the presence of trapped charges on microfabricated devices, in particular with amorphous materials, has been commonly reported31,32,33,34,35. We have developed a theoretical and numerical framework for studying NCF in nanomechanical systems in the presence of static charges and we show that they explain our observations very well. Intriguingly, isolated ultracoherent devices have long shown a persistent discrepancy between measured and predictedQfor their low-frequency modes4,11,12(Fig.1d,e). We show that this discrepancy is most likely due to NCF from the substrate, located tens of microns away. NCF has been modelled in AFM systems as the interaction of a moving point charge with a lossy dielectric28,30. This model can be readily generalized to nanomechanical resonators with distributed electric charges. As shown in Fig.1f, a nanomechanical resonator (for example, a doubly clamped string), with a volume charge densityρe(r){\rho }_{e}({\bf{r}}), is placed near a rigid dielectric body with the complex frequency-dependent permittivity({\epsilon }{r}({\bf{r}},\omega )={\epsilon }{r}^{{\prime} }({\bf{r}},\omega )+i{\epsilon }_{r}^{{\prime\prime} }({\bf{r}},\om