Quantum technologies that rely on mechanical motion—such as ultra-sensitive detectors, frequency converters and quantum memories—need vibrational excitations phonons that remain coherent for a long time.

Quantum technologies that rely on mechanical motion—such as ultra-sensitive detectors, frequency converters and quantum memories—need vibrational excitations (phonons) that remain coherent for a long time. Achieving those long coherence times at gigahertz frequencies has been a persistent challenge, largely because researchers have not had a clear, experimentally grounded picture of what actually causes phonons to lose coherence in the crystalline materials used to build these devices.

A new study tackles that problem by pairing non-invasive laser-based spectroscopy with detailed materials analysis to pinpoint where decoherence originates. The team used micro-fabricated high-overtone bulk acoustic-wave resonators, or μHBARs, as a controlled platform for investigation. These resonators support gigahertz-frequency acoustic modes while keeping “surface participation”—the fraction of the mode’s energy that interacts with the device surface—much lower than in tightly confined nanomechanical structures. In principle, that reduced interaction should mean less noise, less dephasing and longer-lived phonons. Yet previous μHBAR experiments had topped out at coherence times below a millisecond, far shorter than geometry alone would predict, implying that material imperfections were the limiting factor.

By directly probing phonon behavior and correlating it with the state of the resonator material, the researchers found that phonon–surface interactions dominate decoherence in crystalline quartz μHBARs. The evidence points to a compromised near-surface layer as the primary culprit. Specifically, the team identifies likely contributors including lattice distortion, subsurface damage left by fabrication, and elevated levels of elemental impurities concentrated near the surface. In other words, even in a crystal expected to have extremely low internal dissipation at cryogenic temperatures, the surface can effectively become the weak link that governs performance.

Armed with that diagnosis, the researchers refined the fabrication process. They implemented an optimized polishing step designed to remove the damaged and contaminated surface region. The payoff was dramatic: the improved quartz devices reached mechanical quality factors above 240 million at 12 GHz. That figure corresponds to phonon coherence times exceeding 6 milliseconds—an important benchmark for gigahertz mechanical oscillators. The team also reports that dephasing in these resonators is negligible, indicating that the remaining decoherence is largely attributable to energy loss rather than frequency fluctuations that would scramble phase information.

The work lands in the middle of a broader push to control long-lived phonons using multiple quantum platforms, including optomechanical systems, electromechanical circuits and superconducting qubits. High-frequency phonons are especially attractive because they are less susceptible to certain forms of environmental noise, can be brought to their quantum ground state more readily in cryogenic setups, and interface naturally with techniques from quantum optics and circuit quantum electrodynamics.

Beyond demonstrating millisecond-scale coherence at 12 GHz, the authors outline a route toward coherence times longer than 100 milliseconds, positioning high-frequency mechanical modes as a realistic foundation for quantum memories. The central message is practical as well as scientific: improved surface control—reducing roughness, removing damaged layers and limiting impurity concentrations—can sharply cut dissipation and noise, unlocking long-lived phonons that can support many quantum operations within a single coherence window.