Millions of people worldwide are living with movement and sensory impairments owing to spinal cord injury, stroke and other neurological conditions.
Millions of people worldwide are living with movement and sensory impairments owing to spinal cord injury, stroke and other neurological conditions. Here we report a double neural bypass (DNB), a hybrid neuroprosthetic system designed to restore both immediate and lasting gains in movement and sensation after a severe, complete spinal cord injury. The DNB links an intracortical brain–computer interface with targeted and patterned neuromodulation of the spinal cord and cortex. This allows brain signals associated with movement intention to directly control the movement of the user’s own hand in real time while also promoting long-term sensorimotor recovery—even after the system is turned off. The DNB system uses recurrent artificial neural networks and reinforcement learning for fine grasp control, together with patterned spinal cord stimulation and activity-informed intracortical microstimulation (‘cortical mirroring’) to promote neuroplasticity and durable recovery of function. In a participant with chronic C4 sensory/C5 motor complete tetraplegia, this hybrid approach enabled recovery of functional abilities including self-feeding and manipulation of delicate objects, while also producing significant and persistent improvements in elbow flexion and wrist tactile sensation. These findings demonstrate the potential of combining a sensorimotor neuroprosthesis with targeted brain and spinal neuromodulation to restore clinically relevant function in severe paralysis. Spinal cord injury (SCI) is a leading cause of paralysis, with tetraplegia occurring in over half of all cases. Individuals with SCI consistently rank regaining upper limb movement as their highest recovery priority1,2. Furthermore, complete injuries, where no voluntary motor or sensory function is present below the level of injury, are particularly difficult to treat and recovery of useful function is exceedingly rare3. We, and subsequently other researchers, demonstrated that a motor neuroprosthesis using a unidirectional intracortical brain–computer interface (iBCI) linked to real-time muscle stimulation can restore thought-driven functional hand movement in complete tetraplegia4,5. However, this approach did not include tactile sensory feedback, important for skilled grasping, or methods to promote neuroplasticity and persistent sensorimotor recovery. Tactile feedback via intracortical microstimulation (ICMS) of the primary somatosensory cortex (S1)6,7,8,9,10has been previously used to perform tasks with robotic manipulators11,12but not with the user’s own hand. Furthermore, while temporary enhancement of tactile sensation using ICMS has been demonstrated, persistent recovery has remained elusive13. Lastly, iBCI-mediated spinal cord stimulation (SCS) has been demonstrated to recover function, albeit restricted to the lower limbs in incomplete SCI14. To address the unmet clinical need of restoring upper limb function in individuals with high-level, complete SCIs, we developed a ‘double neural bypass’ (DNB)—a hybrid brain–body interface that provides both assistive and therapeutic benefits. To achieve this, the DNB integrates a bidirectional iBCI that records from, and stimulates in, the sensorimotor cortex, a stable neural decoding architecture to infer user intentions, deep reinforcement learning (RL) to support precision movements and transcutaneous SCS (tSCS) to modulate targeted dorsal spinal roots for promoting neuroplasticity and persistent recovery. In our first-in-human DNB clinical trial spanning more than 3 years (Extended Data Fig.1), we enrolled a 42-year-old man with complete C4 sensory/C5 motor tetraplegia resulting from a diving accident 13 months prior. With an inability to lift his arms or hands to his face, hold objects or feel any sensation in his distal forearms and hands, his upper limb sensorimotor functions were severely limited. To restore upper limb functional ability in our study participant, the DNB utilizes several key subsystems that serve the assistive and/or therapeutic modalities. To restore cortically mediated high-precision hand grasping (assistive mode), the DNB uses multiple neural networks (Fig.1a) in a nested closed-loop control architecture that utilizes a long short-term memory (LSTM) neural network and a deep-RL agent. Here, movement intentions are decoded from neural activity recorded via two microelectrode arrays implanted in the primary motor cortex (M1) while specific stimulation patterns are delivered to up to three microelectrode arrays implanted in S1 (Fig.1b). Functional magnetic resonance imaging (fMRI) and cortical parcellation from the Human Connectome Project (HCP)15was used to localize cortical regions of hand representation and plan implantation locations before surgery, with intraoperative cortical stimulation refining the target locations (Fig.1b). Example M1 intracortical activity used as LSTM inputs for different hand movements are shown in Fig.1c. Tactile sensory percepts evoked were localized mostly to the index and thumb pad and the corresponding electrodes that were stimulated are shown in Fig.1d. For both motor and sensory therapeutic modalities, tSCS is delivered through a custom electrode patch16(Fig.1a). For sensory intervention, the iBCI leverages its bidirectional approach to record from, and stimulate in, S1 by attempting to activate similar cortical circuits that are active during imagined sensation. a, Schematic showing the DNB system.b, Top: intraoperative image of the brain showing M1 and S1 with the central sulcus (CS; white). Colored circles in M1 show intraoperative cortical stimulation sites that evoked EMG activation in the right BB (orange) and twitches in the right hand (magenta). Colored circles in S1 show awake intraoperative cortical stimulation sites that evoked sensory percepts in the thumb (red), index (yellow), middle (purple) and pinky (gray) fingers. Dashed and solid squares show planned and actual locations for array implantation, respectively. The black notch in the corner marks the medial sensory array (S1c). Bottom: task fMRI response (zscore) to video-guided imagined and attempted thumb flexion and extension. Black squares are the planned array implantation sites shown on the pial surface using Connectome Workbench, overlaid on cortical areal boundaries from HCP cortical parcellation.c, Examples of M1 electrodes tuned to ‘open’ the hand (left) and ‘close’ the hand (right). Top: mean integrated broadband power (100–5,000 Hz) in M1 with shaded region showing 95% CI (n= 15 trials). Bottom:z-scored power depicting each trial.d, Example somatosensory percepts elicited by S1-ICMS shown to be localized to the thumb and index fingers. Each evoked percept is matched by color to the electrode that elicited it upon stimulation in the inset array. The black notch on the bottom right corner marks the medial sensory array (S1c) as inb(top). The array schematic also indicates electrodes that did not evoke a sensory percept (white squares) and electrodes that were not wired at all (gray squares). The other two sensory arrays (S1a and S1b) did not evoke any sensory percepts. For evaluating the efficacy of the hybrid DNB system, we first sought to establish sensorimotor baselines and assess the extent of functional recovery with tSCS alone. The patient presented with minimal ability to lift his arms off his wheelchair armrests, could not bring his hands to his face and had no volitional finger movement. Sensory assessments using Semmes–Weinstein monofilaments (SWMs) confirmed that he lacked tactile sensation in both hands and wrists. We administered tSCS by stimulating the dorsal cervical spinal column via a custom stimulator and an electronically controllable electrode patch16(Fig.2a) with anatomical landmarks ensuring consistent electrode placement (Fig.2b). Recruitment profile mapping along the rostrocaudal axis was obtained by delivering 3 Hz tSCS through each of the eight electrode rows of the custom patc